top of page

diondo sub micron CT

diondo Sub Micro

Sub-Micro CT System for materials research with the highest resolution,
The compact Sub-Micro-CT System has been developed for analyzing three-dimensional structures in materials research. The sub-µ-resolution captures the finest structures three-dimensionally, which are often to be found in connection with fiber-reinforced materials or organic materials.

  • Innovative Detector System (IDS)
    The IDS provides three different fields of view and a sCMOS camera.
     

  • Compact Design
    The small footprint is due to the integration of the entire periphery.
     

  • High-Precision Manipulator
    The manipulator has piezo-based linear axes and air bearing rotary axis.

CT Indirect Detector System


In contrast to conventional Micro-CT Systems, which work with high magnification, the Sub-Micro-CT Systems owe their high spatial resolution to their innovative x-ray camera, which allows fully automatic switching between three fields of view.

The smallest of them scans your samples with 0.3 μm/voxel and the largest captures a measuring volume of up to 5 mm (1.4 μm/voxel scanning).

Sub Micron Applications

Applications
Nothing remains hidden for these test methods. With a maximum voxel resolution of 300 nanometers they are particularly suited for the three-dimensional analysis of micro structures.

The main areas of application lie in materials research, in particular for lightweight composite materials such as carbon fiber and glass fiber composites in order to determine the density and/or the spatial orientation of the fiber.

Other areas of application are metal alloys (phase fractions and shape within the metal structure), metallic and organic foams (pore size and distribution), as well as natural materials such as wood, bone and stone.

X-Ray Source.....................................20-90 kV, max. 8 Watt

Detector.........................................4 Megapixels CMOS Chip, 6.5 μm Pixel Resolution

Voxel Resolution [µm].............0,3...............0,56.............1,4

Optic.......................................20 x..............10 x............4 x

CT Scan Field [mm]................0,62..............1,2..............2,8

Extended Scan Field [mm]......1,1................2,1.............5,0

System Dimensions.............L 1.170 x B 645 x H 1.615 [mm]

System Weight..........................................................890 [kg]

Manipulation  granite based, 6 piezo-based linear axes, air bearing rotary axis